MODEL | Power (W) |
Voltage (V/HZ) |
Current (A) |
Max.flow (L/min) |
Max.head (m) |
Rated flow (L/min) |
Rated head (m) |
Suction head (m) |
Pipe size (mm) |
GKX200A | 200 | 220/50 | 2 | 33 | 25 | 17 | 12 | 8 | 25 |
GKX300A | 300 | 220/50 | 2.5 | 33 | 30 | 17 | 13.5 | 8 | 25 |
GKX400A | 400 | 220/50 | 2.7 | 33 | 35 | 17 | 15 | 8 | 25 |
GKX600A | 600 | 220/50 | 4.2 | 50 | 40 | 25 | 22 | 8 | 25 |
GKX800A | 800 | 220/50 | 5.2 | 50 | 45 | 25 | 28 | 8 | 25 |
GKX1100A | 1100 | 220/50 | 8 | 100 | 50 | 42 | 30 | 8 | 40 |
GKX1500A | 1500 | 220/50 | 10 | 108 | 55 | 50 | 35 | 8 | 40 |
GKX series of pumps have automatic function, that is, when the tap is turned on, the pump will start automatically; when the tap is turned off, the pump will stop automatically. If it is used with the water tower, the upper limit switch can automatically work or stop with the water level in the water tower. GKX is with streamline product design, novel and generous, in line with the use of various occasions.
Features:
1.New flow channel structure;
2.Low noise;
3.Reduce the pump temperature rise;
4.New design of pump control circuit board;
5.Improved stability;
6.User-friendly
Description of indicator light:
1. Water flow indicator: on: water flow detected, off: no water flow detected
2. Pressure indicator: on: no pressure detected, off: pressure detected
3. Power indicator: flashing: in forced shutdown state, normally on: in normal state
4. Water shortage indicator: flashing: water shortage, off: no water shortage
5. Induction indicator: on: water flow switch fault off: normal state
6. Card indicator: on: rust removal, off: normal state, flashing: forced start / close
7. Timing indicator: set timing time
Using instructions:
1. After power on, delay 3 seconds, start the motor for 6 seconds, and enter the dual control operation mode
2. In the dual control mode, press the timing button for 5S to enter the timing mode, and the timing indicator light is on to indicate the timing time.
3. In the timing mode, press the timing button briefly to switch the timing time.
4. In the timing mode, press the automatic switch button for 5S to re-enter the dual control operation mode.
5.In the timing mode / dual control mode, press the automatic switch button and click start or stop.
Product detail pictures:
Related Product Guide:
We have now our possess revenue group, design staff, technical crew, QC team and package group. We now have strict excellent regulate procedures for each process. Also, all of our workers are experienced in printing subject for Quality Inspection for Inline Water Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING , The product will supply to all over the world, such as: Melbourne, Argentina, Guyana, We welcome you to visit our company, factory and our showroom displayed various products that will meet your expectation, meanwhile, it is convenient to visit our website, our sales staff will try their efforts to provide you the best service. If you need more information, please do not hesitate to contact us by E-mail or telephone.