Online Exporter Centrifugal Monoblock Pump - GKX High-Pressure Self-Priming Pump – GOOKING
Online Exporter Centrifugal Monoblock Pump - GKX High-Pressure Self-Priming Pump – GOOKING Detail:
MODEL | Power (W) |
Voltage (V/HZ) |
Current (A) |
Max.flow (L/min) |
Max.head (m) |
Rated flow (L/min) |
Rated head (m) |
Suction head (m) |
Pipe size (mm) |
GKX200A | 200 | 220/50 | 2 | 33 | 25 | 17 | 12 | 8 | 25 |
GKX300A | 300 | 220/50 | 2.5 | 33 | 30 | 17 | 13.5 | 8 | 25 |
GKX400A | 400 | 220/50 | 2.7 | 33 | 35 | 17 | 15 | 8 | 25 |
GKX600A | 600 | 220/50 | 4.2 | 50 | 40 | 25 | 22 | 8 | 25 |
GKX800A | 800 | 220/50 | 5.2 | 50 | 45 | 25 | 28 | 8 | 25 |
GKX1100A | 1100 | 220/50 | 8 | 100 | 50 | 42 | 30 | 8 | 40 |
GKX1500A | 1500 | 220/50 | 10 | 108 | 55 | 50 | 35 | 8 | 40 |
GKX series of pumps have automatic function, that is, when the tap is turned on, the pump will start automatically; when the tap is turned off, the pump will stop automatically. If it is used with the water tower, the upper limit switch can automatically work or stop with the water level in the water tower. GKX is with streamline product design, novel and generous, in line with the use of various occasions.
Features:
1.New flow channel structure;
2.Low noise;
3.Reduce the pump temperature rise;
4.New design of pump control circuit board;
5.Improved stability;
6.User-friendly
Description of indicator light:
1. Water flow indicator: on: water flow detected, off: no water flow detected
2. Pressure indicator: on: no pressure detected, off: pressure detected
3. Power indicator: flashing: in forced shutdown state, normally on: in normal state
4. Water shortage indicator: flashing: water shortage, off: no water shortage
5. Induction indicator: on: water flow switch fault off: normal state
6. Card indicator: on: rust removal, off: normal state, flashing: forced start / close
7. Timing indicator: set timing time
Using instructions:
1. After power on, delay 3 seconds, start the motor for 6 seconds, and enter the dual control operation mode
2. In the dual control mode, press the timing button for 5S to enter the timing mode, and the timing indicator light is on to indicate the timing time.
3. In the timing mode, press the timing button briefly to switch the timing time.
4. In the timing mode, press the automatic switch button for 5S to re-enter the dual control operation mode.
5.In the timing mode / dual control mode, press the automatic switch button and click start or stop.
Product detail pictures:
Related Product Guide:
We always continually provide you with the most conscientious customer service, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Online Exporter Centrifugal Monoblock Pump - GKX High-Pressure Self-Priming Pump – GOOKING , The product will supply to all over the world, such as: Casablanca, Slovakia, Algeria, Our company insists on the purpose of "takes service priority for standard, quality guarantee for the brand, do business in good faith, to provide professional, rapid, accurate and timely service for you". We welcome old and new customers to negotiate with us. We will serve you with all sincerity!
By Elma from Curacao - 2018.11.04 10:32
The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
By Cara from Lithuania - 2017.09.26 12:12