We now have a skilled, performance team to supply good quality services for our consumer. We often follow the tenet of customer-oriented, details-focused for Constant Pressure Booster Pump , In Centrifugal Pump , Flow Booster Pump , The principle of our organization is usually to provide high-quality items, qualified services, and trustworthy communication. Welcome all friends to place trial order for developing a long-term small business relationship.
Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING Detail:

MODEL Power
(W)
Voltage
(V/HZ)
Current
(A)
Max.flow
(L/min)
Max.head
(m)
Rated flow
(L/min)
Rated head
(m)
Suction head
(m)
Pipe size
(mm)
GKX200A 200 220/50 2 33 25 17 12 8 25
GKX300A 300 220/50 2.5 33 30 17 13.5 8 25
GKX400A 400 220/50 2.7 33 35 17 15 8 25
GKX600A 600 220/50 4.2 50 40 25 22 8 25
GKX800A 800 220/50 5.2 50 45 25 28 8 25
GKX1100A 1100 220/50 8 100 50 42 30 8 40
GKX1500A 1500 220/50 10 108 55 50 35 8 40

GKX series of pumps have automatic function, that is, when the tap is turned on, the pump will start automatically; when the tap is turned off, the pump will stop automatically. If it is used with the water tower, the upper limit switch can automatically work or stop with the water level in the water tower. GKX is with streamline product design, novel and generous, in line with the use of various occasions.

Features:

GKX-8

1.New flow channel structure;
2.Low noise;
3.Reduce the pump temperature rise;
4.New design of pump control circuit board;
5.Improved stability;
6.User-friendly

Description of indicator light:

1. Water flow indicator: on: water flow detected, off: no water flow detected
2. Pressure indicator: on: no pressure detected, off: pressure detected
3. Power indicator: flashing: in forced shutdown state, normally on: in normal state
4. Water shortage indicator: flashing: water shortage, off: no water shortage
5. Induction indicator: on: water flow switch fault off: normal state
6. Card indicator: on: rust removal, off: normal state, flashing: forced start / close
7. Timing indicator: set timing time

GKX-6

Using instructions:
1. After power on, delay 3 seconds, start the motor for 6 seconds, and enter the dual control operation mode
2. In the dual control mode, press the timing button for 5S to enter the timing mode, and the timing indicator light is on to indicate the timing time.
3. In the timing mode, press the timing button briefly to switch the timing time.
4. In the timing mode, press the automatic switch button for 5S to re-enter the dual control operation mode.
5.In the timing mode / dual control mode, press the automatic switch button and click start or stop.


Product detail pictures:

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures

Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING detail pictures


Related Product Guide:

Our company promises all buyers of the first-class products and solutions as well as most satisfying post-sale support. We warmly welcome our regular and new shoppers to join us for Factory Outlets Low Pressure Booster Pump - GKX High-Pressure Self-Priming Pump – GOOKING , The product will supply to all over the world, such as: Slovakia, Philippines, Sacramento, We've been always creating new technology to streamline the production, and give products with competitive prices and high quality! Customer satisfaction is our priority! You can let us know your idea to develop unique design for your own model to prevent too much similar parts in the market! We are going to present our best service to satisfy all your needs! Remember to contact us right away!
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Fanny from Korea - 2018.07.27 12:26
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Lisa from Turkey - 2017.07.28 15:46
    Write your message here and send it to us